Hydraulic Bollard HRB-HS-CT

SPECIFICATIONS

 Test parameters

7500[N3]/80/90:3.5/22.8

 Equivalent to

K12, M50, PAS68, IWA14-1

 Axle load resistance

50 tons

 Structure

Heavy duty

 Top plate

Sand blasted aluminum with flashing light around

 Type of steel

S275 (inner core), finishing 316 stainless steel sleeve

 Traffic light

Red/green LED, 200 mm diameter, steel post 2 m height and electrostatic powder coated

 Power

380 V, 3 Phase, 50-60 Hz (or 220 V/ 440 V etc., three phase, 50-60 Hz optional by a transformer)

 Power failure

Manual hand pump, (or Hydraulic accumulator, DC motor and batteries or UPS (optional))

 Speed

3-5 seconds, in emergency 1.5 seconds (optional)

 Desktop keyboard

Raise, lower, emergency stop, key operated, ‘keyboard in use’ light indicator

 Extra I/O at the PLC

Enough I/O’s to connect any card reader, extra override keyboard etc. later on

 Proximity sensor

Available to sense the position of the bollard

 Dual vehicle safety loop   detector

This detector is used for safety

Motor Power

Min 4 KW, 1500 rpm

 Environmental conditions

-25 °C and +65 °C, %95 non-condensing humidity

 Environmental conditions   (optional)

-40 °C and +70 °C, %95 non-condensing humidity